HAEMATOLOGY

HAEMATOLOGY

THIS SYSMEX XT 2000I IS AUTOMATED HAEMATOLOGY ANALYZER FOR IN VITRO DIAGNOSTIC USE IN HAEMATOLOGY LABORATORY. MANUFACTURED BY SYSMEX CORPORATION, JAPAN A SYNONYM FOR HAEMATOLOGY WORLD OVER. IT CAN OPERATE IN VARIOUS MODES AS PER REQUIREMENT OF THE PATIENTS.

SAMPLER MODE: IT AUTOMATICALLY MIXES, ASPIRATES, AND ANALYSES SAMPLES WITHOUT REMOVING THEIR CAPS, UPTO 50 SAMPLES CAN BE LOADED AT A TIME AND ANALYZED AUTOMATICALLY.

AUTOMATED ESR ANALYZER MODEL VESMATIC 20:- AN AUTOMATED INSTRUMENT CAPABLE OF PROCESSING MULTIPLE SAMPLES AT A FASTER PACE.

IN CAPILLARY MODE, MINUTE AMOUNT OF BLOOD COLLECTED FROM EAR LOBE OR FINGER TIP CAN BE USED, ESPECIALLY USEFUL IN NEONATES; INFANTS, AND SMALL CHILDREN WHERE VENIPUNCTURE IS DIFFICULT. IN THIS MODE, AN ANALYSIS IS PERFORMED AFTER MANUALLY DILUTING THE SAMPLE 1:5 DILUTION AND THE OBTAINED RESULT IS AUTOMATICALLY MULTIPLIED BY FIVE FOR REPORTING. IT ALSO OPERATES IN MANUAL MODE, AND MANUAL CLOSED MODE AS PER NECESSITY.

IT CAN ANALYZE THE RESULTS OF 24 PARAMETERS OF A BLOOD SAMPLE. IT CAN COUNT AND DENOTE RETICULOCYTE % AT DIFFERENT STAGES OF DEVELOPMENT THEREBY HELPING IN ACCESSING THE RESPONSE OF BONE MARROW TO TREATMENT & ENLIGHTENS THE CLINICIAN ABOUT DEVELOPMENT OF RBCS IN MARROW. IT IS ALSO CAPABLE OF GIVING TRUE PLATELET COUNT BY USING SPECIALIZED STAIN IN THROMBOCYTOPENIC PATIENTS, WITH 5 PART DIFFERENTIAL. IT ALSO DETECTS CANCEROUS BLOOD CELLS (BLAST CELLS, IMMATURE CELLS) & ARYPICAL LYMPHOCYTES

The Diagnostic Centre is equipped with D-10 Haemoglobin Analyzer, which is manufactured by renowned Bio Rad Laboratories Inc.

S.No. Name of Test Reason For Test
1 HB A1C For diagnosis and management of diabetes. Gives record of average blood glucose of previous 90 days. As this test does not require FASTING, will encourage more people to get tested for type 2 diabetes and help further reduce the number of people who are undiagnosed, Additionally early detection can made enormous difference in persons quality of life as type 2 diabetes actually can be prevented. An A1c level of approximately 5% indicates the absence of diabetes and according to the revised evidence-based guidelines, an A1c score of 5.7% to 6.4% indicates prediabetes, and an A1c level of 6.5% or higher indicates the presence of diabetes. For optimal diabetic control, the recommended ADA target for most people with diabetes is an A1c level not greater than 7%.
2 HB F In case of anemia�s in childhood, anemia�s not responding to treatment, in cases of repeated jaundice, in populations with high risk of hereditary haemoglobinopathies. In Chhattisgarh state specially castes like Sahu, Verma and Chandrakars in Mahars community in Maharashtra, where it is very common. It should be mandatory to screen for sickle hemoglobin before marriage in endemic areas. These tests are also very important as pre-marital screening procedure in Sindhis, Bengalis and Punjabis as hereditarily haemoglobinopathies are untreatable except bone marrow transplantation which is very expensive and failure rate is quite significant. Since prevention is better than cure applies here.
3 HB S
4 HB D
5 HB E
6 HB D Punjab.
7 HB Lapore
8 HB Bart
9 HB S + G
10 HB Baltimore
11 HB G 11
12 Montgomery
13 HBA2

FLUORESCENT PARALENCE SYSTEM MADE IN USA BY BECKSON & DECONSON, USA FDA APPROVED SYSTEM FOR DETECTION OF MALARIA
HAS REVOLUTIONIZED DIAGNOSIS AND TREATMENT IN MALARIA, THEREBY AVOIDING UNNECESSARY DRUGGING OF PATIENTS, IS CAPABLE OF AVOIDING FALSE POSITIVE AND FALSE NEGATIVE RESULTS, ALSO HELPS IN ACCURATE SPECIES DETECTION, WITH MEASURING QUANTUM OF PARASITEMIA HELPFUL IN PREDICTING PROGNOSIS OF PATIENTS. IT IS A FAST TECHNOLOGY PROVIDING ACCURATE RESULTS WITHIN 15 MINUTES AFTER RECEIPT OF SAMPLE. IN ADDITION IT IS ALSO USEFUL IN DETECTION OF FILARIAL PARASITE TUBERCLE BACILLI, ANTI-NUCLUEAR ANTI BODIES & OTHERS.

AUTOMATED BLOOD COAGULATION ANALYZER MODEL SYMEXCA- 50:- A MULTI-CHANNEL AUTOMATED SYSTEM FOR MEASURING DEFECTS IN COAGULATION SYSTEM OF THE BODY. MAINLY USED TO ACCESS FLUIDITY OF THE BLOOD IN OPERATED CARDIAC PATIENTS ALSO USED FOR ACCESSING COAGULATION STATUS OF THE PATIENTS BEFORE MAJOR SURGERY AND IN DISEASES ASSOCIATED WITH COAGULATION DEFECTS.

AUTOMATED ESR ANALYZER MODEL VESMATIC 20:- AN AUTOMATED INSTRUMENT CAPABLE OF PROCESSING MULTIPLE SAMPLES AT A FASTER PACE. IT REPORTS ESR WITH IN 20 MINUTES & PROCESSES 20 SAMPLES AT A TIME.